Chapter 4 - Managing and Monitoring
Uploading SES Controller Card Firmware
125
Uploading SES Controller Card Firmware
The following information describes the procedures to upload new firmware to the
SES Controller card. The preferred method is to take the enclosure off-line first, then
perform the upgrade. This prevents bus reset errors.
1
Connect one end of the null-modem RS-232 cable to the RS-232 Service port
located on the SES Controller card.
RS-232 Service Port Connection
NOTE:
The cable is a female-to-female DB-9 null-modem serial cable and is
included with the storage system. Refer to “Null-Modem Cable
Specifications” on page 171 for cable specifications.
2
Connect the other end of the cable to either a host system’s RS-232 serial
communication port or a VT-100 type terminal.
3
On the host system, run a terminal emulation program or start the VT-100
terminal.
4
Verify the communication parameters are as follows:
•
9600 Baud
•
8 Data bits
•
1 Stop bit
•
None (parity)
•
Flow Control Off
5
At the cursor, type <Control-E>.
NOTE:
If the terminal program is not communicating, refer to “Setting the
Communications Parameters Automatically” on page 130.
Summary of Contents for OmniStor 4900F Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 38: ...Chapter 1 Getting Started Audible Alarm 24...
Page 58: ...Chapter 2 Topologies and Operating Modes Application of Availability 44...
Page 128: ...Chapter 3 Setup and Installation Powering Off the Storage System 114...
Page 156: ...Chapter 5 Troubleshooting Problems During Bootup 142...
Page 178: ...Chapter 6 Maintenance Replacing the Enclosure 164...
Page 182: ...Appendix A Technical Information Specifications 168...
Page 196: ...Index 182...