Chapter 4 - Managing and Monitoring
VT-100 Interface Enclosure Monitoring
122
VT-100 Interface Enclosure Monitoring
Another feature of the OmniStor 4900F Series storage system is the ability to monitor
itself. The user can interact with the system through a VT-100 terminal interface. The
firmware based monitoring program allows users to view component status and
firmware specific information. You may access this program by connecting a VT-100
terminal to the SES Controller card RS-232 Service port.
To access the monitoring program:
1
Connect one end of the null-modem serial cable to the RS-232 Service port
located on the SES Controller card.
RS-232 Service Port Connection
NOTE:
The cable is a female-to-female DB-9 null-modem serial cable and is
included with the storage system. Refer to “Null-Modem Cable
Specifications” on page 171 for cable specifications.
2
Connect the other end of the cable to either a host system’s RS-232 serial
communication port or a VT-100 type terminal.
3
On the host system, run a terminal emulation program or start the terminal.
4
Verify the communication parameters are as follows:
•
9600 Baud
•
8 Data bits
•
1 Stop bit
•
None (parity)
•
Flow Control Off
5
At the screen cursor, type <Control-E>. The Enclosure Terminal Utility menu
will appear.
Summary of Contents for OmniStor 4900F Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 38: ...Chapter 1 Getting Started Audible Alarm 24...
Page 58: ...Chapter 2 Topologies and Operating Modes Application of Availability 44...
Page 128: ...Chapter 3 Setup and Installation Powering Off the Storage System 114...
Page 156: ...Chapter 5 Troubleshooting Problems During Bootup 142...
Page 178: ...Chapter 6 Maintenance Replacing the Enclosure 164...
Page 182: ...Appendix A Technical Information Specifications 168...
Page 196: ...Index 182...