Section 4
Swapping Sensors
One unique feature of Cobra is that you can quickly and easily replace one
sensor model with another to accommodate your specific application. This
section provides information on the different DRS models available and how to
swap one sensor for another.
Note:
The procedure for swapping laser sensors varies, depending on the
configuration of your Cobra. The procedure for changing sensors on Cobra
systems equipped with the video camera option starts on the following page and
the procedure for changing sensors on Cobra systems not equipped with the
video camera option starts on page 4-8. Be sure to follow the procedure that
applies to your system.
DRS Models
There are four different sensor models available for use with Cobra. This table
lists each model and its specifications.
Model
Sensor
Type
Capture
Range
Z Accuracy
(within capture
range)
Dynamic
Resolution
Spot
Size
Standoff*
DRS-300
Specular
300 µm
1.0 µm
0.125 µm
7-12 µm
17 mm
DRS-500
Specular
500 µm
1.0 µm
0.125 µm
16-23 µm
17 mm
DRS-2000
Diffuse
2000 µm
10 µm
1.0 µm
32-48 µm
31.5 mm
DRS-8000
Diffuse
8000 µm
40 µm
4.0 µm
60-85 µm
50 mm
* Standoff is the distance in Z from the lowest point on the sensor to the
middle of the capture range.
Swapping Sensors
4-1
Swapping
Sensors
Summary of Contents for Cobra DRS-300
Page 1: ......
Page 5: ...This page was left blank intentionally Cobra Laser Profile Scanner Users Guide...
Page 53: ...This page was left blank intentionally 2 32 Installation and Setup...
Page 67: ...This page was left blank intentionally 3 14 Getting Started...
Page 83: ...This page was left blank intentionally 5 6 Adjusting the Sensor Mounting Pad...
Page 87: ...This page was left blank intentionally 6 4 Troubleshooting...
Page 91: ...This page was left blank intentionally A 4 Setting the Display Properties...
Page 100: ......