Installation and Operation Manual
Page 110 of 156
[PVI-XXX.0-YY(-TL) - Rev:1.0]
15.4.3
Rack Interface
Figure 15-8: Rack Interface – Rack Management
In this mode, the main parameters and the
state of every module of the system can be
observed:
•
The symbol
indicates that the
module is operative, while the symbol
identifies the module in alarm
mode. In the area indicated by the
dotted line, the state of the Supervisor
(Inv), of the digital signal processor
(Dsp) and of the type of alarm (Alarm)
can be read.
•
Inverter ID:
shows the serial number
(SN) and the state of the master or
slave of the module (M/S).
•
Inverter Val
: shows the value of the
size selected from the list (
Select Val)
,
in the top right side.
Figure Figure 15-8 shows the content of the
list where the following sizes can be seen:
Voltage [Panel]
: Voltage read by the
supervisor [Vrms]
IN Voltage
: Field voltage [Vrms]
IN Current
: DC input current [Arms]
IN Power
: Input power [W]
Bulk Voltage ½ (+)
: DC voltage on the
internal capa [Vdc]
Bulk Voltage ½ (-)
: DC voltage on the
internal capacities - [Vdc]
Grid Voltage (RS)
: Grid voltage linked to
phases R-S [Vrms]
Grid Voltage (ST)
: Grid voltage linked to
phases S-T [Vrms]
Grid Voltage (TR)
: Grid voltage linked to
phases T-R [Vrms]
Grid Power (W)
: Power sent to the grid
MCU Temp
: Supervisor temperature [°C]
Power Feed Temp
: Internal power supplier
temperature [°C]
Heatsink Temp
: Power dissipater
temperature [°C]