Fault
Prog. no.
Level Standard value
History 20
Date / Time
Fault code 20
6990
E
SW diagnostic code 20
Burner control phase 20
6995
E
Maintenance/special operation
Prog. no.
Level Standard value
Burner hours interval
7040
E
- - - h
Burn hrs since maintenance
7041
E
0 h
Burner start interval
7042
E
- - -
Burn starts since maint
7043
E
0
Maintenance interval
7044
E
- - - months
Time since maintenance
7045
E
0 months
Fan speed ionization current
7050
E
0 rpm
Message ionization current
No | Yes
7051
E
No
Chimney sweep function
Off | On
7130
Eu
Off
Manual control
Off | On
7140
Eu
Off
Controller stop function
Off | On
7143
E
Off
Controller stop setpoint
7145
E
Compulsory heat draw-off DHW
Off | On
7165
E
Off
Telephone customer service
7170
C
- - -
PStick storage pos
7250
E
0
PStick Reg data set
7251
E
PStick command
No operation | Reading from stick | Writing on stick
7252
E
No operation
PStick progress
7253
E
0 %
PStick status
No stick | Stick ready | Writing on stick | Reading from stick | EMC test active |
Writing error | Reading error | Incompatible data set | Wrong stick type | Stick
format error | Check data set | Data set disabled | Reading disabled
7254
E
Configuration of extension modules
Prog. no.
Level Standard value
Function extension module 1
None | Multifunctional | Temps / mode CH1 | Temps / mode CH2 | Temps /
mode CH3 | Rücklaufregler | Solar HW | Primary contr/system pump
7300
C
Heating circuit 2
Relay output QX21 module 1
None | Circulating pump Q4 | El imm heater HW K6 | Collector pump Q5 | Cons
circuit pump VK1 Q15 | Kesselpumpe Q1 | Bypasspumpe Q12 | Alarm output
K10 | heating pump CH3 Q20 | Cons circuit pump VK2 Q18 | System pump Q14
| Heat gen shutoff valve Y4 | Solid fuel boiler pump Q10 | Time setting 5 K13 |
Pufferrücklaufventil Y15 | Solar pump ext exch K9 | Solar ctrl elem buffer K8 |
Solar ctrl elem swi pool K18 | Swimming pool pump Q19 | Flue gas relay K17 |
St tank transfer pump Q11 | Hot water mixing pump Q35 | HW interm circ pump
Q33 | Heat request K27 | heating pump CH1 Q2 | heating pump CH2 Q6 | Hot
water ctrl elem Q3 | Überhitzschutz K11
7301
C
None
9 Settings
7636047 - 02 - 24082015
73
Summary of Contents for eurocondense four 125 kw
Page 19: ...3 2 6 Wiring diagram Fig 3 Wiring diagram 3 Technical specifications 7636047 02 24082015 19 ...
Page 40: ...Fig 22 Legend for application examples part 2 5 Before installation 40 7636047 02 24082015 ...
Page 143: ...13 Appendix 13 1 Declaration of conformity 13 Appendix 7636047 02 24082015 143 ...
Page 146: ...Index 146 7636047 02 24082015 ...
Page 148: ...7636047 02 24082015 ...