Table 69 Slammer cross connection configuration version 2 PIMs (continued)
Legend
1 First Slammer.
2 Second Slammer.
3 Third Slammer.
4 Fourth Slammer.
5 Move the red FC cables when expanding the system to the next larger configuration.
Note: When adding a fourth Slammer, make sure that the first Brick string that is
directly attached to the new Slammer is a SATA Brick (version 2) or an FC RAID
Brick (version 2). This practice helps to avoid an excess of radiated emissions
and to comply with electro-magnetic (EMI) limits. Any existing SATA Brick
(version 1) or FC RAID Brick (version 1) can cascade from the first Brick string of
version 2 Bricks (SATA or FC RAID) attached to the new Slammer. The first
Brick string must always be an SFP-SFP connection instead of an SFP-HSSDC2
hybrid connection.
Table 70 Swapping head-of-string Brick cables
Appendix D Expansion of a Pillar Axiom 600 System Configuration
About Expanding a Pillar Axiom 600 Configuration
215