Figure 60 Slammer bezel LEDs
Legend
1 CU 0
2 CU 1
3 Fault LEDs
4 Activity LEDs
5 Status LEDs
4 Verify that the FAULT LEDs are off.
If they are on at this stage, it is usually because the bezel is not fully seated.
5 For each Brick, make sure that the CU 0 and CU 1 STATUS LEDs are
green.
When there is no I/O activity on a Brick storage enclosure, the RAID
firmware runs a background operation that scans all drives for media errors.
If media errors are found, the firmware performs repair operations. This
background activity causes the ACT LEDs to blink green on the idle system
or Brick. Such activity can take several hours to complete. When host I/O
resumes, this background operation stops. It resumes only when there are
no further I/Os from a host. This ACT LED blink is inhibited for drive scrub.
Chapter 6 Complete the Installation
Verify the Front Status LEDs
123