Malfunctions
11.4 The pump is running but the performance is not correct
D89 FB PH DRIVE
Phase loss of FB frequency inverter
Check the power supply wiring of the concerned
frequency inverter (presence of voltage on R, S
and T terminal plugs)
Check that there is no power cut-off on power-
phases upstream the frequency inverter
W90 R1 PH DRIVE
Phase loss of Roots 1 frequency inverter
W91 R2 PH DRIVE
Phase loss of Roots 2 frequency inverter
D92 FB RS DRIVE
FB frequency inverter memory error
Check the power supply wiring of the concerned
frequency inverter (presence of voltage on R, S
and T terminal plugs)
Check that there is no power cut-off on power-
phases upstream the frequency inverter
W93 R1 RS DRIVE
Roots 1 frequency inverter memory error
W94 R2 RS DRIVE
Roots 2 frequency inverter memory error
W95/D95 R1 SPEED
Roots 1: absence of speed information
Check the cable or sensor on Li4
.
W102/D102 R1 OIL T°
W102 T° Roots 1 > setpoint T
+ 5°C)
Cooling problem
Check the water cooling supply on the pump.
Check that the cooling pipes are not clogged.
Sensor or wiring faulty
Check the temperature reading on HHR as well as
the connections of the sensor on RSV1 TEMP
plug and of the valve on RSV1 VALVES plug
.
Roots 1 solenoid water valve problem
Check the operation and the connection of the
Roots 1 solenoid valve
Check the power supply of Roots 1 solenoid valve
coil.
Incident
Cause
Remedy
Incident
Cause
Remedy
Bad vacuum or no vacuum
Polluted or clogged pump
FB maintenance
Contact your service center.
Internal oil leak
FB maintenance
Contact your service center.
Mechanical noise
Damaged ball bearing
FB maintenance
Contact your service center.
Rotors seizing
FB maintenance
Contact your service center.
Unsynchronized gears
FB maintenance
Contact your service center.
No N2 purge
Incorrect configuration
Reset monitoring configuration ([PURGE CMD]
[ENABLED]) or set the purge manually (
PURGE
key on HHR).