70
Malfunctions
D40 HAZ T° R1 MOT
Roots 1 motor temperature is > 150 °C
Check the water cooling supply on the pump.
Check that the Roots 1 motor is correctly cooled.
Check that the cooling pipes are not clogged.
Sensor not connected
Check the connection of the sensor on
RSV1 MOTOR plug
.
Other problem
Contact your service center.
D41 HAZ T° FB MOT
BF motor temperature is > 150°C
Check the water cooling supply on the pump.
Check that the FB motor is correctly cooled.
Check that the cooling pipes are not clogged.
Sensor not connected
Check the connection of the sensor on
FB MOTOR plug
.
FB mechanical problem
Free the FB manually
.
Other problem
Contact your service center.
D42 HAZ EXT PRESS
SEMI safety sensor problem (overpressure at ex-
haust)
Check the sensor cable condition and sensor op-
eration
Replace the sensor if necessary.
D43 EXH PRESS
SEMI safety sensor problem (nitrogen pressure)
Check the sensor cable condition and sensor op-
eration
Replace the sensor if necessary.
D44 FRAME PRESS
SEMI safety sensor problem (exhaust ventilation)
Check the sensor cable condition and sensor op-
eration
Replace the sensor if necessary.
D46 ALARM T° FB
FB temperature problem
Check the water cooling supply on the pump.
Check the temperature setpoints and alarm
threshold
Check that the water pipe are not clogged.
W51/D51 USER T°
Incorrect monitoring configuration
Check that the [SETTING] [TEMPERATURE][US-
ER T°] is set on [DISABLED].
Incorrect threshold setting
Check the warning or fault thresholds.
Other problem
Contact your service center.
W52/D52 ROOTS 1 T°
Incorrect monitoring configuration
Check that the
[SETTING][TEMPERATURE][Roots 1 T°][CON-
TROL] or [MEASUREMENT] menu has set
thresholds.
Incorrect threshold setting.
Check the warning or fault thresholds.
Cooling problem
Check the water cooling supply on the pump.
Check that the cooling pipes are not clogged.
Sensor faulty
Check the temperature reading on HHR as well as
the connections of the sensor on RSV1 TEMP
plug and of the valve on RSV1 VALVES plug
.
Other problem
Contact your service center.
W54/D54 HEATER
Heater controller disconnected
Check the cable connection on WH plug or if here
is a strap on WH plug
Heater disconnected
Check the cable connection on
J2
heater control-
ler connector.
Other problem
Contact your service center.
W57/D57 LP FB T°
either
LP T° > setpoint T +5°C
FB LP temperature control valve supply problem
Check the proper operation and the connection of
the FB LP water valve
Cooling problem
Check the water cooling supply on the pump.
Check that the cooling pipes are not clogged.
Temperature sensor and/or wiring faulty
Check the temperature reading on HHR as well as
the connections of the sensor on FB LP TEMP
plug and of the valve on FB VALVES plug
.
Other problem
Contact your service center.
or
LP T° < setpoint T -10°C
FB LP water valve problem
Check the condition of the solenoid valve dia-
phragm and its operation.
Temperature sensor and/or wiring faulty
Check the running and the connection of the sen-
sor on FB LP TEMP plug
Other problem
Contact your service center.
PW59/W59/D59 R2 POWER
Roots 2 incorrect threshold setting.
Check the power threshold setting in menu [SET-
TING][POWER ][R2 POWER].
Roots 2 mechanical problem
Check the rotation of the Roots 2 rotors (if possi-
ble).
Other problem
Contact your service center.
Incident
Cause
Remedy