320
Pulse position command value
Unit:
pulse
Displays the pulse position command value.
321
Pulse position current value
Unit:
pulse
Displays the current pulse position value.
322
Pulse position deviation
Unit:
pulse
Displays the pulse position deviation.
323
Command unit command value
Unit:
Axis command unit
Displays the command unit command value.
324
Scaling data (command unit side)
Unit:
Axis command unit
Displays the axis scaling data (command unit side) that is actually used.
325
Scaling data (pulse side)
Unit:
pulse
Displays the axis scaling data (pulse side) that is actually used.
328
Position settling status
Unit:
None
Indicates that the axis position deviation is within the specified range.
335
Interface ready
Unit:
None
Indicates that the PLC interface is ready.
337
Overload status
Unit:
None
Displays the overload status.