Monitor detail
STD1
300
Currently under operation
Unit:
None
Indicates that an operation is being performed.
301
Axis is under operation
Unit:
None
Indicates that an axis operation is being performed.
302
Error status
Unit:
None
Indicates the error status.
303
Alarm status
Unit:
None
Indicates the alarm status.
304
Driver ready
Unit:
None
Indicates that the driver is ready.
305
Servo ready
Unit:
None
Indicates that the servo is ready.
310
Display of program number under execution
Unit:
None
Indicates the program number during execution or after execution.
317
Completion of homing status display
Unit:
None
Indicates whether a homing operation has been completed after the power is turned on.
318
Homing operation: The measured value
Unit:
pulse
Indicates the distance between the neighboring signal and origin that is measured during homing operation.