Error number
45
- direction software over-travel
Error type:
[KIND_ERR] error
Measures:
[TYPE_E2] Stop deceleration.
Long:
Short:
Soft_OT_-_direction
-_Soft_OT
Main cause:
Attempted to move to outside of the - direction area via positioning move, but the command unit
command value was outside of the - direction area.
Action to take:
Perform an error reset operation. If the command unit command value is outside of the area, move to
the + direction. This error occurs only for the linear coordinates.
Error number
46
Emergency stop
Error type:
[KIND_RGR] Always error
Measures:
[TYPE_E2] Stop deceleration.
Long:
Short:
EmergencyStop
EMG_Stop
Main cause:
An emergency stop instruction was entered.
Action to take:
Reset the error.
Error number
49
Homing error
Error type:
[KIND_ERRALM1] Error/operation alarm
Measures:
[TYPE_E2] Stop deceleration.
Long:
Short:
OriginError
OriginErr
Main cause:
An error occurred during homing operation.
[Subcode]
1: Locating fixture position problem
Action to take:
Error number
50
Cannot execute
Error type:
[KIND_ERRALM2] Error/operation alarm
Measures:
[TYPE_E2] Stop deceleration.
Long:
Short:
CantExec
CantExec
Main cause:
Cannot execute.
[Subcode]
1: Prohibited command
2: Execution in progress
3: Error status
4: Data is being used.
5: Invalid data
6: Access timing
7: Driver mode
8: Invalid program file
9: Nesting overflow
Action to take: