COMSPHERE 6800 Series Nework Management System
2-22
August 1994
6800-A2-GB21-10
Configuring the Control Port
To communicate with the 719 NETWORKER and through it to the NMS, you must first verify that
the control port on the 724/735 multiplexer is configured as a supervisory port with the correct
settings.
Supervisory Port
After the terminal or PC and the multiplexer are turned on, the following prompt appears:
Local: menus (y/n) >
To verify that the control port is configured as a supervisory port (to communicate with a 719
NETWORKER), perform the following steps:
1. Access the control mode of the multiplexer,
TYPE: y
PRESS: Enter
The screen displays Local: Enter Password >
2. TYPE: the current password
The default password is enter. The password does not appear on the screen.
PRESS: Enter
The Local/Remote Menu appears.
3. TYPE: 1
PRESS: Enter
to access the Local Menu. The Function menu appears.
4. TYPE: 2
PRESS: Enter
to access the Configuration menu. The Configuration menu appears.
5. TYPE: 4
PRESS: Enter
to access the System Configuration menu. The System Configuration menu appears.