Chapter 7
Appendix
—
Technical information
ENGLISH -
2
9
3
r
ENABLE/DISABLE
Operation for all channels is not accepted
w
hen set to “Disable
”
.
Performance
Parameter
Default value
Disable
0
-
12
7
0
Enable
12
8-
2
55
Note
f
If the projector is operated using the re
m
ote control or the control panel, or by the control co
mm
and
w
hile controlling the projector using the
Art-Net function, the setting of the DM
X
controller or co
m
puter application
m
ay be different fro
m
the projector status. To re
fl
ect the controls
of all channels to the projector, set “ENABLE
/
DISABLE
”
of channel
11
to “Disable
”
and then back to “Enable
”
.
f
To create and register the USER LOGO i
m
age, use “Logo Transfer Soft
w
are
”
. The soft
w
are can be do
w
nloaded fro
m
the
w
ebsite
(
https:
//
prosyste
m
.panasonic.cn
/
ProjectorDo
w
nload
)
.
Control commands via LAN
The projector can be controlled
v
ia the <DIGITAL LINK> ter
m
inal or the <
局域网
> ter
m
inal by using the control
co
mm
and for
m
at
v
ia the <
串口输入
> ter
m
inal.
For exa
m
ples of the a
v
ailable co
mm
ands, refer to “
C
ontrol co
mm
and
”
(
x
page
300)
.
Note
f
To send
/
recei
v
e the co
mm
and
v
ia LAN, it is necessary to set the pass
w
ord of the ad
m
inistrator account.
(
x
page
21
9
)
When connecting in protect mode
Connecting
Follo
w
ing is the connection
m
ethod
w
hen the [NETWORK]
m
enu
→
[NETWORK SE
C
URITY]
→
[
C
OMMAND
PROTE
C
T] is set to [ENABLE].
1) Obtain the IP address and port number (Initial set value = 1024) of the projector and request a
connection to the projector.
f
You can obtain both the IP address and the port nu
m
ber fro
m
the
m
enu screen of the projector.
IP address
Obtain fro
m
the [NETWORK]
m
enu
→
[NETWORK STATUS].
Port number
Obtain fro
m
the [NETWORK]
m
enu
→
[NETWORK
C
ONTROL]
→
[
C
OMMAND PORT].
2) Check the response from the projector.
Data section
Blank
Mode
Blank
Random number section
Termination
symbol
Command
example
“NT
C
ONTROL
”
(
AS
C
II string
)
‘
’
0
x
20
‘
1
’
0
x
31
‘
’
0
x
20
“zzzzzzzz
”
(
AS
C
II code hex nu
m
ber
)
(C
R
)
0
x
0
d
Data length
9 bytes
1
byte
1
byte
1
byte
8 bytes
1
byte
f
Mode:
1
= Protect
m
ode
f
Exa
m
ple: Response during protect
m
ode
(
rando
m
nu
m
ber section is unde
fi
ned
v
alue
)
“NT
C
ONTROL
1
231
8
1
e
1
e
”
(C
R
)
3) Generate a 32-byte hash value from the following data using MD5 algorithm.
f
“xxxxxx:yyyyy:zzzzzzzz
”
xxxxxx
The user na
m
e for the ad
m
inistrator account
yyyyy
The pass
w
ord for the ad
m
inistrator account
zzzzzzzz
8-byte rando
m
nu
m
ber obtained in Step
2)