Chapter 4
Settings — [PICTURE] menu
ENGLISH - 59
6) Press
as
to select [RED], [GREEN], or [BLUE].
f
Only [GAIN] can be adjusted when [WHITE] is selected for [3COLORS].
7) Press
qw
to adjust.
f
The adjustment value will change between 0
*1
and 2 048
*1
.
*1 The limit values vary depending on the color to be adjusted.
Note
f
Operation when correcting the adjustment color
When the correction color same as the adjustment color is changed: The luminance of the adjustment color changes.
When correction color red is changed: Red is added to or subtracted from the adjustment color.
When correction color green is changed: Green is added to or subtracted from the adjustment color.
When correction color blue is changed: Blue is added to or subtracted from the adjustment color.
f
Since advanced skills are necessary for the adjustment, this adjustment should be carried out by a person who is familiar with the projector
or by a service person.
f
Pressing the <DEFAULT> button on the remote control will restore the factory default settings for all items.
Adjusting color matching using a colorimeter
Use a colorimeter that can measure chromaticity coordinates and luminance to change the colors of [RED],
[GREEN], [BLUE], [CYAN], [MAGENTA], [YELLOW], or [WHITE] to desired colors.
1) Press
as
to select [COLOR MATCHING].
2) Press
qw
to select [MEASURED].
3) Press the <ENTER> button.
f
The
[MEASURED MODE]
screen is displayed.
4) Press
as
to select [MEASURED DATA].
5) Press the <ENTER> button.
f
The
[MEASURED DATA]
screen is displayed.
6) Measure the current luminance (Y) and the chromaticity coordinates (x, y) using the colorimeter.
7) Press
as
to select a color, and press
qw
to adjust the setting.
f
Set [AUTO TESTPATTERN] to [ON] to display a test pattern of selected colors.
8) Once all the input is completed, press the <MENU> button.
f
The
[MEASURED MODE]
screen is displayed.
9) Press
as
to select [TARGET DATA].
10) Press the <ENTER> button.
f
The
[TARGET DATA]
screen is displayed.
11) Press
as
to select a color and press
qw
to input coordinates for desired colors.
f
By setting [AUTO TESTPATTERN] to [ON], the test pattern for the selected color is displayed.
12) Once all the input is completed, press the <MENU> button.
Note
f
Colors are not displayed properly when target data is a color outside the region of this projector.
f
Set the [AUTO TESTPATTERN] to [ON] to automatically display a test pattern for use in adjusting the selected adjustment colors.
f
When using a colorimeter or similar instrument to take measurement, measure the colors displayed in [AUTO TESTPATTERN].
f
A difference in the color coordinates of target data and measurement value obtained from an instrument may occur for certain instrument
and measurement environment used.