Chapter 5
Operations — Web control function
ENGLISH - 117
Click [Detailed set up]
→
[E-mail set up].
1
2
3
4
5
6
1 [ENABLE]
Select [Enable] to use the E-mail function.
2 [SMTP SERVER NAME]
Enter the IP address or the server name of the E-mail server
(SMTP). To enter the server name, the DNS server needs to be
set up.
3 [MAIL FROM]
Enter the E-mail address of the projector. (Up to 63 characters
in single byte)
4 [MEMO]
Enter information such as the location of the projector that
notifies the sender of the E-mail. (Up to 63 characters in single
byte)
5 [MINIMUM TIME]
Change the minimum interval for the temperature warning
E-mail. The default value is 60 minutes. In this case, another
E-mail will not be sent for 60 minutes after sending the
temperature warning E-mail even if it reaches the warning
temperature.
6 [INTAKE AIR TEMPERATURE]
Change the temperature setting for the temperature warning
mail. A temperature warning E-mail is sent when the
temperature exceeds this value.
8
7
11
10
9
7 [E-MAIL ADDRESS 1]
Enter the E-mail address to send E-mails.
8 Settings of the conditions to send E-mail
Select the conditions to send E-mail.
[MAIL CONTENTS]:
Select either [NORMAL] or [SIMPLE].
[ERROR]:
Sends an E-mail when an error occurred in the self-diagnosis.
[INTAKE AIR TEMPERATURE]:
Sends an E-mail when the air intake temperature has reached
the value set at the above field.
[PERIODIC REPORT]:
Place a check mark on this to send an E-mail periodically.
E-mails will be sent on the days of week and time with the
check marks.
9 [E-MAIL ADDRESS 2]
If you use the second E-mail address, enter the E-mail address
to send E-mails.
Leave it blank when you do not use the second E-mail address.
10 Settings of the conditions to send E-mail
Select the conditions to send E-mails to the second E-mail
address.
[MAIL CONTENTS]:
Select either [NORMAL] or [SIMPLE].
[ERROR]:
Sends an E-mail when an error occurred in the self-diagnosis.
[INTAKE AIR TEMPERATURE]:
Sends an E-mail when the air intake temperature has reached
the value set at the above field.
[PERIODIC REPORT]:
Place a check mark on this to send an E-mail periodically to the
second E-mail address.
E-mails will be sent at the days of week and time with the check
marks.
11 [Submit] button
Updates the settings.