4.6.6 Setting Up Judgement Criteria in JUDGEMENT CRITERIA and
MEASUREMENT OBJECT MIN. SETTING modes
Based on the base measurement saved by teaching, the allowable limits for OK judgement specified each in
X and Y direction in mm.
Operation in JUDGEMENT CRITERIA SETTING mode
In INSPECTION (or RUN) mode
In JUDGEMENT CRITERIA SETTING mode (“SET” is displayed.)
Referring the value saved during teaching
•
RMinX: Min. in the X direction
•
RMaxX: Max. in the X direction
•
RMinY: Min. in the Y direction
•
RMaxY: Max. in the Y direction
Allowable range to be set
•
PMinX: Min. in the X direction
•
PMaxX: Max. in the X direction
•
PMinY: Min. in the Y direction
•
PMaxY: Max. in the Y direction
•
The <8> button: Increases the value
•
The <7> button: Decreases the value
MinX: Min. for Measurement Object - in the X
direction
•
The <8> button: Increases the value
•
The <7> button: Decreases the value
MinY: Min. for Measurement Object - in the Y
direction
•
The <8> button: Increases the value
•
The <7> button: Decreases the value
92
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...