ST.NO: (1 to 31)
Station Number function:
Sets a device number (unit) used
for RS-232C communication
BAUD.R: (9.6 to 57.6 kbps)
Baud Rate function:
Sets RS-232C communication
speed
OUT.D: (0 to 160 ms) in the 20 ms
Output Delay function:
Outputs inspection results after the
original output timing
CAP.D: (0 to 160 ms) in the 1 ms
unit
Capture Delay function:
Sets the time delay from TRIGGER
signal input to image capture
I.TRR: (ON / OFF)
Internal Trigger function:
When the function is set to ON, the
LightPixAE20 automatically performs
continuous inspections
When OFF, inspection is performed
when TRIGGER signal is input.
INI.T: (1 ~ 7)
Initial Type:
The selected product type number
when the LightPixAE20 is turned on
(available only for colored areas)
SPEED: High / Middle / Low
Speed:
Allows you to select the processing
time of measurement (available
Color Judgement only)
VER
Version:
Version, size of view range and
system and operation unit versions.
(Size of view range differs
depending on the product number.)
Color Area
Color Judgement
T.TRG: (ON / OFF)
Teaching Trigger function:
Sets external trigger to ON (valid) or
OFF (invalid)
A.BACK: (ON / OFF)
Answer back function:
Displays the detection position in
blue on the finder unit.
36
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...