4.4.6 Inspection
Execution
The Ways of Inspection Execution
Internal trigger: ON
Inspection is automatically performed by switching to RUN mode.
Internal trigger: OFF
After switching to RUN mode, input the TRIGGER signal to external devices or
press the TRIGGER button.
Inspection Judgement Results
Judgement results are output to the parallel ports of OUT1 to OUT3 as the table shown below
Judgement Results
OUT3 OUT2 OUT1
OK
Edge was detected and the detected edge distance
is within the “base di/- allowable range.
OFF
OFF
ON
NG Except those above
OFF
OFF
OFF
Checking the measured data
When executing an inspection in RUN mode, you can check the X- and Y- directional distance of the
detected edge.
Display
data
switch
or
Upper line: Product type number and type of data
Type of data: X/Y
•
X: X-directional distance of the detected edge
•
Y: Y-directional distance of the detected edge
Lower line: Data value
•
Detection edge distance: Four digits including the
numbers under the decimal point)
(The number of digits under the decimal point differs
depending on the type of unit.)
When the unit failed to detect an edge, the screen
display is as the figure on the right.
Data type in the edge direction saved by teaching and the
data are displayed.
Product
type
switch
The <3>, <4> and <5> buttons:
Changes the product types
Once you change the product
types, OUT1 to 3 are reset.
*Range of data
Type
Data
ANE2000
ANE2010
ANE2020
ANE2030*
X
0 to 2.00
0 to 10.00
0 to 30.00
0 to 80.00
Y
0 to1.60
0 to 8.00
0 to 25.00
0 to 70.00
*The view range changes within the range of 70 x 56 to 100 x 80 depending on the installation position of
ANE2030, but the position data are converted into mm based on the range of view 80 x 70. Therefore, if you
use the unit out of the view range 80 x 70, the position data differs from the actual size.
Input/Output Timing: Page 102
69
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...