4.2.3 Setting Procedures and Modes
The LightPixAE20 can be configured following the steps below:
1
Set up devices.
Install the main unit and connect to a power supply unit,
each unit and external devices.
Section 3
2
Turn the LightPixAE20 on.
Apply 24 V DC
-
3
Configure the
LightPixAE20.
(in CONFIGURATION mode)
Set up the LightPixAE20 system in CONFIGURATION
mode.
Inspection/communication conditions and hardware settings
of the unit
Page 35
4
Run teaching.
(in TEACHING mode)
In the TEACHING mode, register extraction color, at the
same time, set the exposure time or range for measuring
area (inspection area), and area for setting extraction color.
Page 37
5
Set judgement criteria
(in JUDGEMENT CRITERIA
SETTING mode).
In JUDGEMENT CRITERIA SETTING mode, set the limits
of area values (min. to max.). If the area values are within
the limit, the LightPixAE20 judges as OK.
Page 41
6
Execute an inspection
(in RUN / RUNVIEW mode)
Press the TRIGGER button in RUN (RUN VIEW) mode.
Page 42
There are four modes available for the LightPixAE20. The settings that you can make vary depending on the
mode. To switch the modes, follow the instructions below.
34
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...