3.4.3 Output
Signal
Circuit
Output part: PhotoMos relay
The output load should be within the specified range. See the figure shown below.
Notes on Parallel Output
•
Leakage current at the time of output signal OFF is less than 100 µA.
•
The LightPixAE20 has a low load capacity so that you can connect the LightPixAE20 to a PLC, etc. Do
not connect directly with a device having a high load capacity such as a valve without passing it through
our Power-Photo relay.
•
The output circuit contains no built-in fuse. If it is necessary to prevent from burning out the output
circuit in the event of output load short circuit, mount a fuse externally. However, it may not be able to
protect internal elements in the event of short circuit.