Type of
item
Item
Com-
mand
Register
No.
Setting
value
range
Remarks
Initial
Setting)
WD 3900 1
Type of
Teaching
RD/WD
0: OK only / 1: OK&NG
4100
0-1
Save
Image
Condition
RD/WD 4200
0-2
0:OFF / 1:All Images / 2:NG Image only
Teaching
Trigger
RD/WD 4700
1/0
(Trigger signal receive when executing a teaching)
1: On (Receive trigger signal)
0: Off (Do not receive trigger signal)
RD/WD 4800
0/1
0: ON / 1: OFF
Backlight
Pattern
RD/WD 4900
0-3
0: ON / 1: OFF10 / 2: OFF30 / 3: OFF60
Auto Save RD/WD 5000
0/1
0: ON (the Auto Save function is activated.)
1: OFF (the Auto Save function is canceled.)
Detailed
Setting
RD/WD 5400
0/1
1: ON (Make the detailed settings)
0: OFF (Not make the detailed settings)
5500 1-50 The
first
step
Number of
Detected
Candidates
RD/WD
5501 1-50 The
second
step
Condition: Should be less than the value set for the
fist step
0-50 The
first
step
CONFIGURA
TION
Similarity
Adjusteme
nt
RD/WD
5501 0-50 The
second
step
Allowable
Range (the
number of
pixels)
RD/WD 5100
-
5113
X: 0-357
Y:0-288
Product type 1: X = 5100 Y = 5101 / Product type 2: X =
5102 Y = 5103 / Product type 3: X = 5104 Y = 5105 /
Product type 4: X = 5106 Y = 5107 / Product type 5: X =
5108 Y = 5109 / Product type 6: X = 5110 Y = 5111 /
Product type 7: X = 5112 Y = 5113
Allowable
range
(mm)
RD/WD 5114
-
5141
Depends
on the
type of
unit
Actual values and double-word type
Product type 1:
X = 5114&5115 Y = 5116&5117
Product type 2:
X = 5118&5119 Y = 5120&5121
Product type 3:
X = 5122&5123 Y = 5124&5125
Product type 4:
X = 5126&5127 Y = 5128&5129
Product type 5:
X = 5130&5131 Y = 5132&5133
Product type 6:
X = 5134&5135 Y = 5136&5137
Product type 7:
X = 5138&5139 Y = 5140&5141
Threshold
of
Similarity:
(%)
RD/WD 5200
-5213
0-100
Product type 1: 5200 / Product type 2: 5201 / Product type
3: 5202 / Product type 4: = 5204 / Product type 5: 5205 /
Product type 6: 5205 / Product type 7: 5206
Base
Distance
(the
number of
pixels)
RD/WD 5300
-
5313
X: 0-357
Y:0-288
Product type 1: X = 5300 Y = 5301 / Product type 2: X =
5302 Y = 5303 / Product type 3: X = 5304 Y = 5305 /
Product type 4: X = 5306 Y = 5307 / Product type 5: X =
5308 Y = 5309 / Product type 6: X = 5310 Y = 5311
Product type 7: X = 5312 Y = 5313
JUDGEMEN
T CRITERIA
SETTING
Base
Distance
(mm)
RD/WD 5314
-
5341
Depends
on the
type of
unit
Actual values and double-word type
Product type 1: X = 5314&5315 Y = 5316&5317
Product type 2: X = 5318&5319 Y = 5320&5321
Product type 3: X = 5322&5323 Y = 5324&5325
Product type 4: X = 5326&5327 Y = 5328&5329
Product type 5: X = 5330&5331 Y = 5332&5333
Product type 6: X = 5334&5335 Y = 5336&5337
Product type 7: X = 5338&5339 Y = 5340&5341
Answer
Back
5501
121
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...