Item
Description
Applica-
tion
CAP.D: (0 ~ 160 ms) 1
ms
Capture Delay
Indicates the waiting time for the LightPixAE20 to capture the image
after the TRIGGER signal input
But, the READY signal is turned off without delay after the TRIGGER
signal is input, irrespective of the Capture Delay time.
Inspection time (READY signal OFF time) will become longer by the
amount of the Capture Delay time
All
I.TRR: (ON / OFF)
Internal Trigger
To select whether or not to execute an inspection by receiving the signal
to from the external device
•
ON:
Automatic continuous inspections (no need to receive the
TRIGGER signal from the external device)
•
OFF:
Executes an inspection for each TRIGGER signal input from the
external device
All
INI.T: (1 ~ 7)
Initial Type
Product type No. that is called when turning on the LightPixAE20
All
SPEED: (High / Mid /
Low)
Speed
Select your desired inspection speed from the following three options.
You can speed up the LightPixAE20 by changing the speed in the
following order:
Low -> Middle -> High
Every time you change the speed, the “computation time” is also
changed. Speed for each application is as the table shown below:(Unit:
ms)
High
Middle
Low
Color Jdgement
20
50
150
Color Pattern
100
200
500
Edge Detection
10
15
20
Measurement 15 20 30
If you set Speed to Middle or High, the unit scans the 352 pixels
(horizontal) x 288 pixels (vertical) by skipping some of them. Therefore,
the inspection results differ depending on the setting value.
Refer to the pages describing the Color Pattern Matching.
Color
Judgement
/ Color
Pattern
Matching /
Edge /
Measurem
ent
T.TRG: (ON / OFF)
Teaching Trigger
When the TRIGGER signal is input from the external device, you can
select whether or not execute a teaching.
•
ON: TRIGGER signal on
The LightPixAE20 executes a teaching after the TRIGGER signal
input TRIGGER
•
OFF: TRIGGER signal off
The LightPixAE20 executes a teaching only when the TRIGGER
button is pressed. It does not execute a teaching even when the
TRIGGER signal is input.
The setting of this function is effective only in TEACHING mode, not in
other modes.
All
96
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...