6.4.5 Measurement
Type of
item
Item
Com-
mand
Data
register
No.
Setting
value
range
Remarks
1100
0 - 352
X-directional minimum value
1101
0 - 288
X-directional maximum value
1102
Y-directional mininum value
Detection
Length
(Unit:pixel)
RD
1103
Y-directional maximum value
Judgement
Results
RD 1104 0/1 1:
OK
0: NG
Measurem
ent Time
RD 1105
1106-1107
X-directional minimum value
1108-1109
X-directional maximum value
1110-1111
Y-directional minimum value
Detection
Length
(mm)
RD
1112-1113
Depends
on the
type of
unit
Y-directional maximum value
Product
Type
RD/WD 1400
1-7
WD: Switches the product types
RD: Reads the current product type
Inspection
Start
WD
1500
1
Starts an inspection
READY RD 1600
0/1
ALARM RD 1601
0/1
LOCK RD/WD 1602 0/1
1: ON
0: OFF
Mode
RD/WD 1603
0-2
0: RUN mode
1: RUN/VIEW mode
2: TEACH mode
3: CONFIGURATION mode (support for RD)
4: JUDGEMTN CRITERIA SETTING mode (support
for RD)
OUT1 RD 1604 0/1
OUT2 RD 1605 0/1
INSPECTION
OUT3 RD 1606 0/1
1: ON
0: OFF
2100 Product
type1
2101 Product
type2
2102 Product
type3
2103 Product
type4
2104 Product
type5
Product
type
6
Exposure
Setting
Time
RD/WD
2106
0003
-5000
Product type 7
WD:
Used for running a teaching in data
area 2500 using “1” (without
exposure time adjustment).
RD:
Reads the current exposure time
2200
Product type 1: X coordinate at upper left
2201
Product type 1: Y coordinate at upper left
2202
Product type 1: X coordinate at lower right
2203
Product type 1: Y coordinate at lower right
2204-2207 Product
type
2:
X coordinate at upper left - Y coordinate at lower right
2208-2211 Product
type
3:
X coordinate at upper left - Y coordinate at lower right
2212-2215 Product
type
4:
X coordinate at upper left - Y coordinate at lower right
2216-2219 Product
type
5:
X coordinate at upper left - Y coordinate at lower right
2220-2223 Product
type
6:
X coordinate at upper left - Y coordinate at lower right
INSPECTI
ON AREA
SETTING
RD/WD
2224-2227
X:351-0
Y:287-0
Product type 7:
X coordinate at upper left - Y coordinate at lower right
TEACHING
Teaching
Results
RD 2300 0/1 0:
OK
1: NG (the ALARM signal is also output.)
2105
128
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...