Operation in TEACHING mode
The number in < > in the table below represents the button number of the o
unit (see the figure on the right).
peration
TEACH: OK (teaching for OK product only)
TEACH: OK (teaching for OK product only)
In INSPECTION (or RUN)
mode
In TEACHING mode (“TEACH” is displayed)
Exposure time: 0.03 to 50.00 ms
(default: 3.05)
<7>: Decrease exposure time up to
0.03 ms
<8>: Increase exposure time up to
50.00 ms
SIZE: Resizes the inspection area
If you want to perform a teaching at
this point, press <6> and then <1>.
MOVE: Moves the inspection area
If you want to execute teaching, press
<6> and then <1>.
T.SIZE: Resizes the Color
Extraction area
If you want to execute a teaching at
this point, press <6> first and then <1>
after resizing.
T.MOVE: Moves the Color
Extraction area
<6>: Executes a teaching
Teaching is performed for the current
product type.
DONE: Indicates successful
completion of teaching
FAIL: Indicates unsuccessful
completion of teaching
(the ALARM signal is output).
<5> : Returns to the top.
You can always
change the
product types by
pressing <2> and
<5> at the same
time.
Example:
38
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...