4.5 Peak Detection
4.5.1 Overview of Peak Detection
In a binarized image, the unit detects a point in the inspection area. If the base point saved in TEACHING
mode is detected, and the distance between the left upper of the point in the inspection area where the point
is detected and the detected point is within the base po/- allowable range, the image is judged as OK,
and OUT1 is turned ON.
Detectable and undetectable peaks
The unit detects two points in the X and Y directions by computing the intersected point. The X- and Y-
directional distance between the left upper part of the point in the inspection area and the detected point is
displayed as a the position of the detected point in mm.
Example detectable images
These are examples of black objects against a white background, but the unit can also detect a white
object against a black background.
Undetectable image