Even if you selected X-directional measurement direction in CONFIGURATION mode, Y-directional
base length and the allowable range do not affect the inspection results. Similarly, even if you
selected Y-directional measurement direction in CONFIGURATION mode, X-directional base length
and the allowable range do not affect the inspection results.
4.6.7 Measurement
Execution
The ways of mesurement execution
Internal trigger: ON
Measurement is automatically executed by switching to RUN mode.
Internal trigger: OFF
After switching to RUN mode, input the TRIGGER signal to external devices or
press the TRIGGER button.
Judged measurement results
The LightPixAE20 outputs these judgement results to parallel ports of OUT1 to OUT3
Judgement results
OUT3 OUT2 OUT1
All OK
Both maximum and minimum are
within the base /-value for
judgement base criteria
OFF
ON
ON
MAX:OK Only maximum value is within the
range
OFF
ON
OFF
MIN: OK Only minimum value is within the
range
OFF
OFF
ON
All NG
Both maximum and minimum values
are beyond the range, or the unit
failed to measure a length.
OFF
OFF
OFF
Internal Trigger: Switches ON/OFF in CONFIGURATION mode
Parallel input/output timing chart: Page 102
93
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...