Checking measurement data
When carrying out measurement in RUN mode, you can check the minimum and maximum of the detected
length in the X and Y directions. When setting the direction of the inspection object in CONFITURATION
mode to X, you can check the default or previous settings by selecting Y, but you should not refer to the
settings.
Display
data
switch
Upper line: Product type number and data type
Data type: MinX / MaxX / MinY / MaxY
•
MinX: Minimum in the X direction
•
MaxX: Maximum in the X direction
•
MinY: Minimum in the Y direction
•
MaxY: Maximum in the Y direction
•
Time: Calculation time
Lower line: Data value
•
Detection length: Up to four digits* including the
numbers under the decimal point
The unit failed to detect any length, the display on
the display is as the figure shown right
•
Calculation time: Up to two digits* including the
numbers under the decimal point
If the detection direction is set to either X or Y, the
measurement data for unselected direction are not
displayed.
Product
type
switch
The <3>, <4> and <5> buttons:
Change the product types
Once you switch the product types,
the outputs to the ports of OUT1 to
OUT3 are reset.
*Data range
Unit type
Data
ANE2000
ANE2010
ANE2020
ANE2030*
X
0 to 2.00
0 to 10.00
0 to 30.00
0 to 80.00
Y
0 to1.60
0 to 8.00
0 to 25.00
0 to 70.00
*The view range changes within the range of 70 x 56 to 100 x 80 depending on the installation position of
ANE2030, but the position data are converted into mm based on the range of view 80 x 70. Therefore, if you
use the unit out of the view range 80 x 70, the position data differs from the actual size.
94
Summary of Contents for LightPix AE20
Page 8: ...Chapter 1 Overview of Light Pix AE20 1 ...
Page 12: ...Chapter 2 Names and Functions of Parts 5 ...
Page 18: ...Chapter 3 Installation and Wiring 11 ...
Page 36: ...Chapter 4 Inspection Applications 29 ...
Page 106: ...Section 5 Parallel Communication 99 ...
Page 113: ...Section 6 RS 232C Communication 107 ...
Page 138: ...Section 7 About AETOOL and GT11 133 ...
Page 143: ...Section 8 General Specifications Product Numbers and Dimensions 139 ...
Page 148: ...Mounting plate Operation unit 144 ...
Page 149: ...Finder unit 145 ...
Page 150: ...Record of Changes Manual No Date Descriptions ARCT1F406E May 2005 First Edition 146 ...
Page 151: ...ARCT1F406E 200505 P 2005 ...