High-speed
Counter Function
10-14
10.3.4 Sample Program (Positioning Operation With Inverter: First Speed)
Counts the feedback signals from the encoder with the high-speed counter. The operation of
the inverter stops when the count value reaches 5000.
Wiring example
Operation chart
I/O allocation table
I/O no.
Description
I/O no.
Description
X0
Encoder input
R100
Positioning operation is running.
X5
Operation start signal
R101
Positioning operation start.
Y0
Inverter operation signal
R102
Positioning done pulse
R9110
High-speed counter CH0 control flag