Instruction
References
7-30
Operation result storage area
Operand Settings
Description
⑤
S+12
X-axis Component speed
Initial speed Fxmin
The component speed (initial speed and maximum speed of
each axis) is stored as 2 words in real type.
(Composite speed)
×
(X-axis movement amount)
X-axis component speed =
((X-axis movement amount)
2
+ (Y-axis movement amount)
2
)
(Composite speed)
×
(Y-axis movement amount)
Y-axis component speed =
((X-axis movement amount)
2
+ (Y-axis movement amount)
2
)
Example) Even when the initial speed is corrected, the
calculated value is stored as is in the operation result storage
area.
S+14
X-axis Component speed
Maximum speed Fxmax
S+16
Y-axis Component speed
Initial speed Fymin
S+18
Y-axis Component speed
Maximum speed Fymax
⑥
S+20
X-axis
Frequency range
The frequency ranges are automatically selected by the system
for the components of each axis.
0: Low speed range (1 Hz to 22 kHz)
1: High speed range (50Hz to 100 kHz)
When the initial speed (X/Y axis) is the low speed range and the
maximum speed (X/Y axis) exceeds 22 kHz, the initial speed
(X/Y axis) is corrected to 50 Hz.
When the initial speed (X/Y axis) is less than 1 and the
maximum speed (X/Y axis) exceeds 22 kHz or less, the initial
speed (X/Y axis) is corrected to 1 Hz.
S+21
Y-axis
Frequency rangec
⑦
S+22
X-axis
Acceleration/deceleration
steps
The acceleration/deceleration steps are automatically calculated
by the system in the range of 0 to 60 steps.
・
When the operation result is 0, the pulse output is
performed at the initial speed (composite speed) without
acceleration and deceleration.
・
The acceleration/deceleration steps are calculated by the
following formula; Acceleration/deceleration time (ms) x
Initial component speed (Hz).
Example) When the settings are as follows; Incremental, Initial
speed=5 kHz, Acceleration/deceleration time=0.5 s, CH0 target
value=1000, and CH2 target value=50.
(1000
2
+50
2
)
= 299.626 Hz
300×1000
(1000
2
+50
2
)
= 14.981 Hz
300×50
CH0 Initial component speed =
CH2 Initial component speed =
CH0 Acceleration/deceleration steps = 500x10
-3
x299.626≈147.8
60 steps
CH2 Acceleration/deceleration steps = 500x10
-3
x14.981≈7.4
7 steps
S+23
Y-axis
Acceleration/deceleration
steps
Supplement to pulse output operation
When outputting pulses with the PLS+SIGN (direction output) method, pulses will be output
approx. 300µs later after the output of direction signal (SIGN). (The characteristics of a motor
driver is considered.)
Summary of Contents for FP0H Series
Page 1: ......
Page 11: ...1 Functions of Unit and Restrictions on Combination ...
Page 19: ...2 Wiring ...
Page 23: ...3 Power ON and OFF and Items to Check ...
Page 30: ...Power ON and OFF and Items to Check 3 8 ...
Page 31: ...4 Settings of Control Unit ...
Page 52: ...Settings of Control Unit 4 22 ...
Page 53: ...5 Operation Patterns ...
Page 89: ...6 Operating Characteristics ...
Page 93: ...7 Instruction References ...
Page 124: ...Instruction References 7 32 ...
Page 125: ...8 Troubleshooting ...
Page 133: ...9 PWM Output Function ...
Page 140: ...PWM Output Function 9 8 ...
Page 141: ...10 High speed Counter Function ...
Page 151: ...10 3 High speed Counter Instruction 10 11 MEMO ...
Page 170: ......
Page 171: ...11 FPΣ Mode ...
Page 180: ...FP Mode 11 10 ...
Page 181: ...12 Specifications ...
Page 196: ...Specifications 12 16 ...
Page 198: ......
Page 199: ......
Page 200: ......