Operation
Patterns
5-18
Settings
Item
Setting example
Axis setting area
Startup speed
1,000 Hz
Table area
Table number
Table 1
Control code
Increment mode
Operation pattern
E-point control (End point control)
Positioning acceleration time
100 ms
Positioning deceleration time
200 ms
Positioning target speed
20,000 Hz
Positioning movement amount
100,000 pulses
Dwell time
50 ms
Configurator PMX settings
Sample program
The execution condition is differential execution. For details of instructions, refer to "7
R1
(
)
DF
K1
K0
F380 POSST
K0
X808
CH0
BUSY
CH No.0
Table no. 1
Position control starts.