Troubleshooting
8-6
8.2.2 What to Do When Positioning Error Occurs
The following are the solutions when the self-diagnostic error (error code 44: positioning error)
occurs.
Positioning error code
Error
code
Error name
Description
Operation when an error
occurs and solution
10H
Limit + signal detection
The input on the plus side of the limit turned
on. (Note)
The operation stops in the limit
stop time specified in the axis
setting area.
After the stop, execute the
home return or JOG operation
in the reverse direction.
Correct the setting of the
parameter.
11H
Limit - signal detection
The input on the minus side of the limit
turned on. (Note)
12H
Limit signal error
Both inputs on the plus and minus sides of
the limit turned on.
20H
Axis setting error
The axis setting is incorrect.
Each control operation does not
start. Correct the setting of the
parameter.
21H
Limit stop deceleration
time error
The set value of the limit stop deceleration
time is out of the range.
22H
Emergency stop
deceleration time error
The set value of the emergency stop
deceleration time is out of the range.
23H
Startup speed error
The set value of the startup speed is out of
the range.
24H
Home return setting code
error
The set value of the home return setting
code is out of the range.
25H
Home return target speed
error
The set value of the home return target
speed is out of the range.
26H
Home return acceleration
time error
The set value of the home return
acceleration time is out of the range.
27H
Home return deceleration
time error
The set value of the home return
deceleration time is out of the range.
28H
Home return creep speed
error
The set value of the home return creep
speed is out of the range.
29H
Home return direction error The set value of the home return direction is
out of the range.
30H
JOG operation target
speed error
The set value of the JOG operation target
speed is out of the range.
31H
JOG operation
acceleration time error
The set value of the JOG operation
acceleration time is out of the range.
32H
JOG operation
deceleration time error
The set value of the JOG operation
deceleration time is out of the range.
(Note): The error occurs only when the condition of the limit stop is satisfied.
Summary of Contents for FP0H Series
Page 1: ......
Page 11: ...1 Functions of Unit and Restrictions on Combination ...
Page 19: ...2 Wiring ...
Page 23: ...3 Power ON and OFF and Items to Check ...
Page 30: ...Power ON and OFF and Items to Check 3 8 ...
Page 31: ...4 Settings of Control Unit ...
Page 52: ...Settings of Control Unit 4 22 ...
Page 53: ...5 Operation Patterns ...
Page 89: ...6 Operating Characteristics ...
Page 93: ...7 Instruction References ...
Page 124: ...Instruction References 7 32 ...
Page 125: ...8 Troubleshooting ...
Page 133: ...9 PWM Output Function ...
Page 140: ...PWM Output Function 9 8 ...
Page 141: ...10 High speed Counter Function ...
Page 151: ...10 3 High speed Counter Instruction 10 11 MEMO ...
Page 170: ......
Page 171: ...11 FPΣ Mode ...
Page 180: ...FP Mode 11 10 ...
Page 181: ...12 Specifications ...
Page 196: ...Specifications 12 16 ...
Page 198: ......
Page 199: ......
Page 200: ......