background image

Neets Control - LiMa

Installation Manual

Summary of Contents for LiMa

Page 1: ...Neets Control LiMa Installation Manual ...

Page 2: ...r notice Questions AFTER reading this manual can be addressed to your local distributor or Neets A S Langballe 4 8700 Horsens Denmark by E Mail Support Neets dk or you may use our contact form at www neets dk Revision list This document has the following revision changes Author Date Description Pages Rev TBB 09 08 2018 First release All 1 00 What is in the box When you open the box it will contain...

Page 3: ...omponents inside These openings must never be blocked by other objects Do not use this equipment near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture and objects filled with liquids Unplug the product before cleaning Clean only with a dry cloth and not cleaning fluid or aerosols Such products could enter the unit and cause damage fire or electric...

Page 4: ...rs other AV devices with feedback functionality 2 General Purpose I O ports Used for input output control of relays switches and sensors 2 Built in low voltage relays Used for contolling external devices such as electrical screens Ethernet port Used for controlling 10 LAN and 8 Neets extension devices and connection to Central Control and Project Designer as well as access to graphical user interf...

Page 5: ...output No Max voltage load 24 VDC Max current 0 5 A Connector 3 pin screw block Relay Output Voltage max 30 VDC Current max 0 5 A Connector 2 pin screw block Network LAN Speed 10 100 Mbit Duplex modes Half or Full DHCP Default off Default IP 192 168 254 252 Default gateway 192 168 1 1 Default subnet mask 255 255 255 0 PoE input Compliance 802 3af 802 3at 802 3af PD mode A B PD Class 0 802 3af 4 80...

Page 6: ...on a ceiling with the included self tapping screws Unpack the unit place the unit on the surface where it is to be mounted and screw the two screws through the holes in the top as shown below The unit also can be mounted in a 19 inch standard rack using the Neets Rack Shelf Part number 306 0017 See separate manual for installation instructions designed in Denmark Neets Control LiMa control Config ...

Page 7: ...the I Os When an IO is configured as input the yellow LED marked in will illuminate when the input is high and turn off when the input is low The green LED marked out will remain off When an IO is configured as output the green LED marked out will illuminate when the output is high and turn off when the output is low The yellow LED marked in will remain off Connection and Controls Front Number Des...

Page 8: ...r about 1mm by using your finger tip Release again and it will slide out REMEMBER to remove power from unit power down before re moving uSD card Power and Error Indication The on LED will show the current status of the unit Green Neets Control LiMa is on and running normally Blue Neets Control LiMa is starting Flashing red The Neets Control LiMa is in error mode see section Error indication on pag...

Page 9: ...plate R G T2 R2 G T1 R1 PoE IN When used as RS 232 transmit port Connect the device to T1 R1 and GND as shown here above When used as single IR port Connect the IR emitter to T1 white striped wire and GND as shown above When used as dual IR port Connect the IR1 emitter to T1 white striped wire and black wire on IR1 emitter to IR2 emitter white striped wire and black wire from IR2 emitter to GND as...

Page 10: ...tionality The LAN connector is used to connect the LiMa to the local area network The LiMa has Power over Ethernet functionality built into the LAN interface connector You must connect the LiMa to your LAN if you are using any of the LAN features of the product The port features auto MDI X which means that you can connect the LAN port directly to other devices without the need for a LAN switch The...

Page 11: ... REV1 G T2 R2 G T1 R1 PoE IN 310 0305 002 003 REV2 Silkscreen Bottom plate PN 310 0305 www neets dk Relays 1 2 3 4 G PWR NCL NDA NEB LAN I O ports G 1 2 4 3 G 5 6 8 7 G T2 R2 G T4 T5 G T1 R1 G T3 R3 PoE IN PoE OUT Relays 1 2 3 4 G PWR NCL NDA NEB LAN I O ports G 1 2 4 3 G 5 6 8 7 G T2 R2 G T4 T5 G T1 R1 G T3 R3 PoE IN PoE OUT 310 0305 002 003 REV2 Silkscreen Bottom plate PN 310 0305 www neets dk R...

Page 12: ...efore reconnecting the power again Unexpected Error Turn off the power to the Control System for 20 seconds before turning the power on again If the error is not resolved contact Neets or your local distributor No contact to Neets network unit Check to confirm that the serial number used in Project Designer matches the Neets extension unit Check the network or RS 232 connection from the Control Sy...

Reviews: