Streaming format
Make settings for H.264 images for use in RTMP/RTMPS
transmission.
The setting is confirmed with the [Set] button.
Refer to the explanation for H.264 (→ page 113) for information
about Image capture size, Frame rate and Max bit rate(per client).
<NOTE>
• Streaming format settings cannot be changed during RTMP/RTMPS
transmissions.
• Set the Streaming format to the settings recommended for the
transmission destination server. Visit the publisher’s website or
contact them about the recommended values.
• When [IP(UDP)] of [Tracking Data Output] is set to [On], video
transmission via IP may be delayed or the video may suffer frame
loss. (→ page 136)
We recommend [IP(UDP)] of [Tracking Data Output] is set to [Off]
during RTMP/RTMPS transmission.
z
SRT
Make SRT transmission settings.
<NOTE>
• When starting SRT transmissions in the [Listener] mode, set the
decoder and application to [Client] mode and set the following URL:
srt://[unit’s IP address]:[value set in Client port]
• When performing SRT transmissions in the [Client] mode, set the
IP address and port number of the decoder and application to
[Destination IP address] and [Destination port], and then click the
[start] button for [Live Streaming] in the live screen [Live].
Common setup
The setting is confirmed with the [Set] button.
Mode [Client, Listener]
Selects the method to connect to the SRT compatible decoder or
service.
Client
Specify the transmission destination IP address and port
number when starting transmission from this unit.
Listener
Specify the listener port when awaiting the external request
to start transmission.
Factory settings:
Listener
Destination IP address
When [Client] is set in [Mode], enter the IP address.
Images and audio will be sent to the specified IP address.
<NOTE>
• Only IPv4 can be set as the IP address.
Destination port
When [Client] is set in [Mode], enter the port number (used when
transmitting images from this unit).
Connection is to the specified port number.
Client port
When [Listener] is set in [Mode], enter the port number (used when
this unit is waiting for a connection).
The following port numbers are used by the unit so they cannot be
used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 546,
547, 554, 995, 5960 to 5985, 7960 to 8060, 10669, 10670, 11900,
59000 to 61000
116
117
Web screen configurations (continued)