PA-7000 Series Firewall Installation
STEP 6 |
After you install each AMC, push the handle in to lock the AMC in place. For more
information on how to install or remove AMCs, see
Replace a PA-7000 Series Firewall LPC
.
After you power on the chassis for the first time, the firewall will format the drives
and configure them in two RAID 1 configurations. The first two drives on the left (A1
and A2) are configured in a RAID 1 pair and the second two drives (B1 and B2) on
the right are configured in a second RAID 1 pair. If the AMCs contain 1TB drives the
total log storage capacity is 2TBs; if the AMCs contain 2TB drives the total capacity is
4TBs.The initial formating and RAID configuration will take approximately 3 minutes.
To check drive status, see
Verify the PA-7000 Series Firewall LPC Configuration
STEP 7 |
Proceed to
Install a PA-7000 Series Firewall Network Processing Card (NPC)
.
Install the PA-7000 Series Firewall Log Forwarding Card (LFC)
is required for chassis operation and the same LFC model is used
in both the PA-7050 and PA-7080 firewalls. On a PA-7050 firewall, you must install the LFC in
slot 8 and on the PA-7080 firewall, you must install the LPC in slot 7.
STEP 1 |
PA-7000 Series Firewall Log Forwarding Card (LFC) Requirements
STEP 2 |
Put the provided ESD wrist strap on your wrist ensuring that the metal contact is touching
your skin. Then attach (snap) one end of the ground cable to the wrist strap and remove the
alligator clip from the banana clip on the other end of the ESD grounding cable. Plug the
banana clip end into one of the ESD ports located on the front of the chassis before handling
ESD sensitive hardware. For details on the ESD port location, see
STEP 3 |
Power off the chassis and disconnect the power cords.
PA-7000 Series Firewall Hardware Reference
92
©
2023 Palo Alto Networks, Inc.