PA-7000 Series Firewall Installation
STEP 5 |
Click the
Log Card Forwarding
tab.
STEP 6 |
Enter the IPv4 and/or IPv6 IP Address, Netmask, and Default Gateway.
STEP 7 |
Click
OK
and then click
Commit
. After the commit completes, connect the port to your
network equipment.
STEP 8 |
Verify that the log port is sending and receiving traffic by viewing logical interface counters.
To view counters, run the following command:
admin@PA-7050>
debug
log-card-interface info slot s8
If counters are incrementing, but traffic is not reaching to the remote server, you can ping the
server from the log port by running the following command:
admin@PA-7050>
debug
log-card-interface ping slot s8 host <host-ip-address>
The firewall will now use this port to forward dataplane logs, email, and WildFire file
forwarding.
For complete details on configuring log forwarding, refer to the
Install a PA-7000 Series Firewall Data Processing Card (DPC)
in a PA-7050 firewall and up to 9 DPCs in a PA-7080 firewall to
expand data processing performance. On a PA-7050 firewall, you can install DPCs in slots 1, 2, 3,
5, 6, and 7 and on a PA-7080 firewall, you can install DPCs in slots 1, 2, 3, 4, 5, 8, 9, 10, 11, and
12.
The procedures to install DPCs in a single chassis and the procedure to install DPCs in a pair of
chassis in high availability (HA) are slightly different.
•
Install a PA-7000 Series Firewall DPC in a Single Chassis
•
Install a PA-7000 Series Firewall DPC in a High Availability (HA) Configuration
Install a PA-7000 Series Firewall DPC in a Single Chassis
STEP 1 |
Put the provided ESD wrist strap on your wrist ensuring that the metal contact is touching
your skin. Then attach (snap) one end of the ground cable to the wrist strap and remove the
alligator clip from the banana clip on the other end of the ESD grounding cable. Plug the
banana clip end into one of the ESD ports located on the front of the chassis before handling
ESD sensitive hardware. For details on the ESD port location, see
STEP 2 |
Remove the DPC from the antistatic bag and partially slide it into any of the available DPC
slots, ensuring that the handles are in the open position. When the card is about 1/4-inch
PA-7000 Series Firewall Hardware Reference
102
©
2023 Palo Alto Networks, Inc.