PA-7000 Series Firewall Installation
STEP 9 |
are properly inserted and then turn on each of the four AC
power switches located on the back of the chassis. The chassis will power on.
Connect DC Power to a PA-7050 Firewall
The following procedure describes how to connect power to DC power supplies in a PA-7050
firewall. The DC power supplies require -40VDC to -60VDC power input. For details on power
requirements, see
Determine PA-7000 Series Firewall Power Configuration Requirements
For the DC input circuit, make sure there is a 60-amp protected circuit breaker, minimum
-40VDC to -60VDC, and a double pole on the input to the DC power. The power cables
used to connect DC power are provided with the PA-7050 firewall, but not the PA-7080
firewall.
STEP 1 |
.
STEP 2 |
Put the provided ESD wrist strap on your wrist ensuring that the metal contact is touching
your skin. Then attach (snap) one end of the ground cable to the wrist strap and remove the
alligator clip from the banana clip on the other end of the ESD grounding cable. Plug the
banana clip end into one of the ESD ports located on the front of the chassis before handling
ESD sensitive hardware. For details on the ESD port location, see
.
STEP 3 |
Remove the two nuts and star washers from the ground studs located on the back of the
chassis on the upper left side.
PA-7000 Series Firewall Hardware Reference
112
©