Service the PA-7000 Series Firewall Hardware
system raid detail
The following output shows that the S7A array is Available.
At this point, drive A2 will show
not in use
because you have not added it to
the new RAID 1 array configuration.
Disk Pair S7A Available
Status clean/degraded
Disk id A1 Present
model : ST2000NX0253
size : 1907738 MB
status : active sync
card serial : 002901000063
Disk id A2 Present
model : ST2000NX0253
size : 1907738 MB
status : not in use
card serial : 002901000064
6. Add the second drive to the new array (A2 is this example):
admin@PA-7080>
request
system raid slot s7 add A2
The system will copy the data from A1 to A2 to mirror the drives.
Continue running the
show system raid detail
command to view the RAID
output until the disk pair status shows
clean
and both disks show
active sync
.
7. To upgrade the B1/B2 drive array, repeat these procedures replacing the drive
designators. For example, replace A1 with B1 and A2 with B2 to upgrade the drives in
the B1/B2 RAID 1 array.
PA-7000 Series Firewall Hardware Reference
207
©
2023 Palo Alto Networks, Inc.