Service the PA-7000 Series Firewall Hardware
supply door toward you from the left side to eject the power supply from the chassis. Then
pull the power supply toward you and remove it.
STEP 5 |
Remove the replacement power supply from the packaging and open the front ejector door
until it is fully open. Remember to push the metal clip located on the bottom left to release
the ejector door.
STEP 6 |
Slide the new power supply into the empty power supply slot until it is almost fully seated.
Ensure that the notch near the hinged part of the ejector door inserts into the chassis so that
when you close the door, it properly seats the power supply.