PA-7000 Series Firewall Overview
Item Component
Description
2
Ground stud
Two-post stud used to ground the chassis to earth ground.
Use the provided 6 AWG two#post ground lug to connect
a grounded cable (not included) to the two#post stud.
3
Power Entry Module
(PEM) AC power inlets
Connects the power source to the power supplies located
on the front of the chassis. The front power supplies
distribute power to all chassis components.
The AC PEM contains four 20-amp AC power inlets—each
accompanied by a switch—one pair, inlet with switch, for
each power supply.
If you are facing the back of the chassis, the inlet and
switch on the far left side provides power to the power
supply on the far right side when facing the front of the
chassis.
The AC PEMs are not field-serviceable.
4
Power Entry Module
(PEM) AC power switches
Provides switches to power on or off the AC power
supplies. Each switch has a circuit breaker that will trip if
the load reaches 25-amps.
PA-7080 Front Panel (DC)
The following image shows the front panel of the PA-7080 firewall (with DC power supplies
installed).
The only difference between the front panel of the AC model and the front panel of the DC
model is that the DC model can hold up to eight DC power supplies instead of AC power
supplies. For descriptions of the front panel components, see
information on connecting power, see
Connect Power to a PA-7000 Series Firewall
.
PA-7000 Series Firewall Hardware Reference