Service the PA-7000 Series Firewall Hardware
card serial : 002901000064
To upgrade the B1/B2 drive array, repeat these procedures replacing the drive designators.
For example, replace A1 with B1 and A2 with B2 to upgrade the drives in the B1/B2 RAID 1
array.
STEP 5 |
Upgrade the firewall from 1TB to 2TB drives if the firewall is running PAN-OS 7.0.7 or
earlier:
The logs on the 1TB drives will not be available after the upgrade. We recommend that
you perform this upgrade during a maintenance window.
To retain logs, you must upgrade to PAN-OS 7.0.8 and follow the procedure described
in
Upgrade the firewall from 1TB to 2TB drives if the firewall is running PAN-OS
.
1. To remove the first two 1TB drives (A1 and A2 in this example) from the RAID 1 array,
run the following commands and enter
y
when prompted to confirm the requests:
admin@PA-7080>
request
system raid slot s7 remove A1
PA-7000 Series Firewall Hardware Reference
204
©
2023 Palo Alto Networks, Inc.