Service the PA-7000 Series Firewall Hardware
STEP 6 |
(
Same model replacement drive only
) Install a replacement drive that is the same model as
the other drive in the RAID 1 array:
1. Pull the AMC handle on the replacement drive outward until it stops to prepare it for
installation into the LPC.
2. Install the replacement drive by gently sliding it into the empty AMC slot (slot A2 in this
example) and then push the release handle inward until it stops to lock the AMC to the
LPC.
3. Add the replacement drive to the RAID 1 array. In this example, run the following
command to add drive A2 to the array:
admin@PA-7080>
request
system raid slot s7 add A2
The system will automatically configure the new drive to mirror the other drive in the
RAID 1 array.
4. View the RAID status until you see that the disk pair (S7A in this example) shows
Available
and both disks show the status
active sync
. To view RAID status, run
the following command:
admin@PA-7080>
show
system raid detail
5. The following output shows that the RAID 1 array is functioning properly:
Disk Pair S7A Available
Status clean
Disk id A1 Present
model : ST91000640NS
size : 953869 MB
status : active sync
card serial : 002901000061
Disk id A2 Present
model : ST91000640NS
size : 953869 MB
status : active sync
card serial : 002901000072
PA-7000 Series Firewall Hardware Reference
187
©