Service the PA-7000 Series Firewall Hardware
6. Install the second replacement drive. In this example, physically remove the drive from
slot A1 and then install the second replacement drive—one that is the same model as you
installed in slot A2—into slot A1.
7. Add the second replacement drive to the RAID 1 array. In this example, run the following
command to add drive A1 to the array:
admin@PA-7080>
request
system raid slot s7 add A1
The system will automatically configure the new drive to mirror the other drive in the
RAID 1 array.
8. Continue to view the RAID status until you see that the drive array (S7A in this example)
shows
Available
and both drives show the status
active sync
.
admin@PA-7080>
show
system raid detail
The following output shows that the RAID 1 array is functioning properly:
Disk Pair S7A Available
Status clean
Disk id A1 Present
model : ST1000NX0423
size : 953869 MB
status : active sync
card serial : 002901000089
Disk id A2 Present
model : ST1000NX0423
size : 953869 MB
status : active sync
card serial : 002901000067
PA-7000 Series Firewall Hardware Reference
189
©