Chapter 4
Replace Slammer Chassis
103
Pillar Data Systems Confidential
After you replace this FRU, Guided Maintenance restarts the
entire Slammer.
Before you remove a Slammer chassis, label each cable that
you detach. The label should note where the cable needs to
be reattached on the CUs in the replacement chassis.
• Power cords. Each of the four power supplies has one
power cord.
• Public Ethernet cables that connect to the LAN. Each
Slammer chassis has two network interface modules,
one for each CU. Each network interface module has two
network ports. One or both of these ports on each
module has a gigabit Ethernet cable.
• Private Ethernet cables that interconnect the Slammers
and the Pilot. The ETH ports have 100Base-T Ethernet
cables attached to them.
• Private Fibre Channel cables that interconnect the
Slammers and the Bricks. The number of Fibre Channel
cables attached to the FC and FS ports on each private
interconnect module depends on the number of
Slammers and Bricks in your Axiom system.
To replace a Slammer chassis, perform the tasks that are
outlined in
Table 28 Slammer chassis replacement tasks
Guided
Maintenance
Task
External to Guided
Maintenance
1
(optional).
2
.
3