Replace Slammer Power Supplies
82
Pillar Data Systems Confidential
After the system is prepared, Guided Maintenance displays a
completion message and enables the Next button.
To remove a Slammer power supply:
1 After Guided Maintenance enables the Next button in the
Prepare step, click the Next button.
2 When Guided Maintenance prompts you, remove the
power cord from the target power supply.
Important!
Do not remove the power cord from the other
power supply. The target control unit (CU) is operational
in conservative mode.
3 Slide the power supply’s release tab to the left and pull
the loop to disengage the power supply from the
midplane.
4 Slide the power supply out of the Slammer chassis and
set it aside.
CAUTION
Immediately replace the component to maintain
proper airflow and cooling. Over-temperature conditions will
occur if the replacement FRU is not installed into the chassis.
Over-temperature conditions can damage other components.
CAUTION
When you remove a power supply, voltage is
present from the partner power supply. Do not insert any
instruments or tools into the open slot.
Insert a Slammer Power Supply
After you insert this FRU into a Slammer control unit (CU),
use Guided Maintenance to finish the procedure.
!
!