Appendix G
Brick Hardware Specification
282
Pillar Data Systems Confidential
Brick Packaging and Transportation
Packaging meets the following requirements:
• For packages under 150 lb—International Safe Transit
Association (ISTA 2A) Procedures 1 and 2.
• For packages over 150 lb—Network Equipment Building
System (NEBS) core standards.
Table 121 Brick EM emissions & immunity
Standard
•
CISPR 22-A
•
EN55022 Class A radiated & conducted emissions (110v/220v)
•
EN55024 Immunity:
•
EN 61000-3-2
•
EN 61000-3-3
•
EN 61000-4-2 ESD: ±4 kV contact, ±8 kV air
•
EN 61000-4-3 Radiated immunity (within the limits that are
listed in our technical specifications)
•
EN 61000-4-4 Electrical fast transients/burst: ±1 kV AC,
±0.5 kV I/O
•
EN 61000-4-5 Surges ±1 kV differential mode, ±2 kV
common mode
•
EN 61000-4-6 Conducted immunity: 3 V
•
EN 61000-4-11 Supply dips and interruptions: 30% & 100%