Chapter 4
Replace Slammer Motherboard Trays
67
Pillar Data Systems Confidential
5 Follow the appropriate procedure in this guide to remove
the battery from the target motherboard tray.
6 Loosen and disengage the two screws that secure the
motherboard tray ejectors to the target Slammer chassis.
7 Press both ejectors down firmly to disengage the
motherboard tray from the chassis midplane.
8 Slide the motherboard tray out of the chassis and set it
aside.
Insert a Slammer Motherboard Tray
After you insert this FRU to a Slammer control unit (CU), use
Guided Maintenance to complete the replacement process.
After you add the FRU and reattach the power cords, Guided
Maintenance fails back the target CU from its partner CU.
Note: When the target CU fails back, if CIFS is enabled on
the Slammer, user data paths will pause for up to 30 sec.
Important!
If Guided Maintenance encounters a problem
during failback, you must contact Technical Support to
continue Guided Maintenance for this FRU.
When the FRU replacement process is complete, the Pillar
Axiom system reports the status of the FRU.
Important!
When you replace this FRU, slowly and evenly
slide the replacement into place. If the FRU has ejectors or
locking tabs, use them for final connector seating.