Chapter 4
Replace Slammer Chassis
106
Pillar Data Systems Confidential
After the system is prepared, Guided Maintenance displays a
completion message and enables the Next button.
CAUTION
Slammers weigh 100 lb (45.4 kg). To handle them
safely, use an appropriate number of persons.
To remove a Slammer chassis:
1 After Guided Maintenance enables the Next button in the
Prepare step, click the Next button.
2 When Guided Maintenance prompts you to replace the
Slammer chassis, flip the PDU circuit breaker(s) that
supply power to the Slammer to their off positions. Be
sure to power off both control unit (CUs) of the target
Slammer.
Tip: When you disconnect the cables, be sure to label
each cable to identify the plug or port to which they were
connected. These labels will be useful when you
reconnect them to the FRUs in the replacement chassis.
3 Disconnect the following cables from the Slammer:
• Four power cables—two for each CU.
• Two to four public Ethernet cables—one or two for
each network interface module.
• Private Ethernet cables—two for one-Slammer
systems and five for two-Slammer systems. These
cables interconnect the Slammers and the Pilot.
• All Fibre Channel cables, which connect to the
Bricks.
!