Chapter 5
Replace Brick ES Modules
129
Pillar Data Systems Confidential
To insert an Enclosure Services (ES) module:
1 Slide the ES module replacement into the Brick chassis
until the module stops.
2 Firmly push the ES module into place to engage it with
the chassis midplane.
Tip: After you install the module, the module performs a
self test, which can take up to 10-15 sec. The system will
not recognize the ES module until it completes this self
test. It is recommended that you wait 10-15 sec before
you perform Step 4.
3 Tighten the Phillips screw to secure the ES module to the
chassis.
Note: The Axiom system does not use the SCSI address
toggle.
4 In the Axiom Storage Manager, click the Next button.
5 On the Verify page, choose one of these options:
• If Guided Maintenance displays a verification failed
message, choose one of these options:
• Click the Try Again button and reseat the FRU.
If the second attempt is successful, click the Next
button; otherwise, you will need to contact
Technical Support to continue Guided
Maintenance for the FRU.
• Click the Exit button and contact Technical
Support.
• Click the Finish button, when Guided Maintenance
enables it.