Monitoring System Components
Monitoring Components and Identifying SNMP Messages
255
■
“System Firmware Components” on page 261
■
“Hard Disk Drive Components” on page 262
Cooling Unit Components
The system has 3.5-inch fan modules with two fans in each module. The following table lists
the system cooling unit components.
Component Name (Oracle
ILOM CLI Targets)
IPMI Type
Description
Values (if applicable)
/SYS/
MB/FM[0-3]
FRU
Fan module FRU
/SYS/
MB/FM[0-3]/F[0-x]
FRU
Individual fan
/SYS/
MB/FM[0-3]/PRSNT
Discrete
sensor
Fan module is present.
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/
MB/FM[0-3]/F[0-x]/
TACH
Threshold
sensor
Fan module fan speed
RPM
/SYS/
MB/FM[0-
3]/SERVICE
Indicator
Fan Service Required LED
Color: Amber
Location: Motherboard
Off: Normal
On: Fan module was diagnosed as
faulty.
Related Information
■
“System Chassis Components” on page 253
■
“Disk Backplane Components” on page 255
■
“Memory Device Components” on page 256
■
“Power Unit Components” on page 257
■
“Processor Components” on page 258
■
“System Board Components” on page 259
■
“System Firmware Components” on page 261
■
“Hard Disk Drive Components” on page 262
Disk Backplane Components
The following table lists the disk backplane (DBP) components.
Summary of Contents for EXADATA X6-2
Page 1: ...Part No E62171 02 June 2016 Oracle Server X6 2 Service Manual ...
Page 2: ......
Page 12: ...12 Oracle Server X6 2 Service Manual June 2016 ...
Page 62: ...62 Oracle Server X6 2 Service Manual June 2016 ...
Page 226: ...226 Oracle Server X6 2 Service Manual June 2016 ...
Page 278: ...278 Oracle Server X6 2 Service Manual June 2016 ...